Performance of succinylacetone assays and their associated proficiency testing outcomes
Adam BW , Hall EM , Meredith NK , Lim TH , Haynes CA , De Jesus VR , Hannon WH . Clin Biochem 2012 45 (18) 1658-63 BACKGROUND: Succinylacetone (SUAC) is the primary metabolic marker for hepatorenal tyrosinemia. MATERIALS AND METHODS: We used results reported for dried-blood-spot proficiency testing (PT) specimens and hepatorenal tyrosinemia patients' newborn screening (NBS) samples to demonstrate analytic biases in SUAC recoveries and differences in presumptive clinical classifications. RESULTS: SUAC recoveries from non-kit and NeoBase kit tandem mass spectrometry methods were markedly different. Kit users that set high cutoff values submitted discordant clinical assessments of "within normal limits" for PT specimens enriched with 10-15mcmol SUAC/L in blood. SUAC levels in tyrosinemia patients' NBS samples analyzed by NeoBase kit were lower than those in samples analyzed by non-kit methods. CONCLUSIONS: From 2009 to 2011, analytic biases in SUAC recoveries were consistent. Discordant clinical assessments of PT specimens were associated with high cutoff values for NeoBase kit results. Method-related differences in SUAC concentrations of tyrosinemia patients' samples were consistent with those of PT specimens. |
The stability of markers in dried-blood spots for recommended newborn screening disorders in the United States
Adam BW , Hall EM , Sternberg M , Lim TH , Flores SR , O'Brien S , Simms D , Li LX , De Jesus VR , Hannon WH . Clin Biochem 2011 44 1445-50 OBJECTIVE: We aimed to measure separately the contributions of heat and humidity to changes in levels of 34 markers of inborn disorders in dried-blood-spot (DBS) samples. DESIGN AND METHODS: We stored paired sets of DBSs at 37 degrees C for predetermined intervals in low-humidity and high-humidity environments. Marker levels of all samples in each complete sample set were measured in a single analytic run. RESULTS: During the 30+/-5day studies, galactose-1-phosphate uridyltransferase and biotinidase lost almost 65% of initial activities in low-humidity storage; most of the degradation in 27 other markers was attributable to adverse effects of high-humidity storage; seven markers in DBSs stored at high humidity lost more than 90% of initial levels by the end of the study and 4 of the 7 lost more than 50% of initial levels within the first week of storage. CONCLUSIONS: Minimizing both humidity and temperature in DBS transportation and storage environments is essential to maintaining sample integrity. |
Detection of TPN contamination of dried blood spots used in newborn and metabolic screening and its impact on quantitative measurement of amino acids
Chace DH , De Jesus VR , Lim TH , Hannon WH , Clark RH , Spitzer AR . Clin Chim Acta 2011 412 1385-90 BACKGROUND: Markers derived from dextrose (d-glucose) are observed in the MS/MS-based acylcarnitine profiles from dried-blood spots of some premature infants receiving intravenous nutrition. The presence of these markers at m/z 325, 399 and 473 are thought to arise from contamination of blood by total parenteral nutrition (TPN) solutions during specimen collection from premature infants. These solutions contain high concentrations of amino acids and as a result, false-positive screening results for amino acid disorders may occur. This study investigates quantitative parameters of dextrose and amino acids in blood samples enriched with different TPN solutions. METHODS: Whole blood collected in heparin was enriched with three different TPN solutions containing 5, 10 or 12.5% dextrose and amino acids that were originally prepared for delivery of 2.5, 3 or 4g/kg/day of Premasol(R) then spotted onto filter paper cards. Acylcarnitine and amino acid profiles using MS/MS were obtained. Ion ratios of dextrose relative to specific acylcarnitine stable isotope internal standards and amino acid concentrations were obtained. RESULTS: The ion ratios for each of the dextrose markers at m/z 325, 399 and 473 exhibit linearity with the concentration of the dextrose component of TPN added to blood. The lowest detectable dextrose concentration added to blood was 7.6mmol/l at 1:80v/v TPN in blood. Furthermore, the concentrations of amino acids were linear with the concentration of the amino acid component of TPN added to blood. At the lowest detectable concentrations of dextrose marker, the amino acid concentrations were at or above the values considered abnormal in newborn screening laboratories. The molar ratios of amino acids approached the relative quantity of amino acid in the TPN solution with increasing enrichments in blood. CONCLUSIONS: Detection of the combinations of dextrose markers, very high elevations of amino acids and unusual molar ratios can be used to reject a specimen as improperly collected rather than declaring it a false positive and hence reduce false positive rates. This process enhances efficiency, reduces parental anxiety, and improves positive predictive values. |
Proficiency testing outcomes of 3-hydroxyisovalerylcarnitine measurements by tandem mass spectrometry in newborn screening
Lim TH , De Jesus VR , Meredith NK , Sternberg MR , Chace DH , Mei JV , Hannon WH . Clin Chim Acta 2010 412 631-5 BACKGROUND: The use of tandem mass spectrometry (MS/MS) for the analysis of amino acids and acylcarnitines from dried-blood spots (DBS) has become routine practice in newborn screening laboratories. The Newborn Screening Quality Assurance Program (NSQAP) added 3-hydroxyisovalerylcarnitine (C5OH) into its routine quality control and proficiency testing (PT) DBS materials for MS/MS to assure the quality of C5OH screening. We report the results from NSQAP evaluations for C5OH-enriched DBS, and summarize participant screening practices based on their analytical methods. METHODS: NSQAP prepared C5OH-enriched DBS materials for its participants. Laboratories reported quantitative and qualitative results. Bias plots of quantitative results were constructed using reported data and the results were sorted by analytical method. RESULTS: NSQAP participants reported PT specimen 3964 as outside of normal limits for C5OH. The mean C5OH value for derivatized and non-derivatized methods was 2.80 and 2.67mumol/l, respectively. Reported data from other specimens showed a similar trend in derivatized vs. non-derivatized assay results. Differences in C5OH quantitative values were observed among laboratories using different internal standards. CONCLUSIONS: C5OH MS/MS measurements in DBS assays varied by method and the choice of internal standards. The use of NSQAP's DBS materials allows harmonization of C5OH measurements by newborn screening laboratories worldwide. |
Tandem mass spectrometric identification of dextrose markers in dried-blood spots from infants receiving total parenteral nutrition
Chace DH , De Jesus VR , Lim TH , Hannon WH , Spitzer AR . Clin Chim Acta 2010 411 1806-16 BACKGROUND: The false positive rate for the newborn screening of disorders of amino acid metabolism for premature infants is higher than full term infants. This may be due to very low birth weight infants receiving high concentrations of amino acids from total parenteral nutrition (TPN) administration and/or immature metabolism. An investigation of the possible influence of TPN on screening of premature infants resulted in the detection of three unusual peaks in the tandem mass spectrometry (MS/MS) acylcarnitine profile. These markers were closely correlated with the detection of very high multiple amino acid increases in the profiles of newborns administered with TPN and who were ultimately found to be normal and free of inherited metabolic disorders. METHODS: TPN solutions contain a concentrated mixture of amino acids and dextrose and other nutrients in saline. Due to its high concentration and suggestion of a carbohydrate, it was hypothesized that dextrose (D-glucose) was the contaminant and source of the markers detected. Dextrose, stable isotope-labeled 13C6-dextrose and various TPN solutions were analyzed directly or after enrichment in whole blood by multiple MS/MS acquisition modes including MS-only, product and precursor ion and neutral loss scans. RESULTS: Analysis of dried-blood spots (DBS) prepared from whole blood spiked with TPN solutions containing 12.5% dextrose and amino acid formulations designed to deliver 2.5 gm/kg/day of an amino acid mixture had moderate increases of all 3 dextrose markers detected at m/z 325, 399 and 473 as compared to controls. MS-only scans, product and precursor ion scans of dextrose and 13C6-dextrose in positive ion mode confirmed that these 3 peaks are derived from dextrose. Mass spectral analysis of labeled and unlabeled dextrose suggested that these peaks were dimers derived from dextrose. CONCLUSION: The identification of dextrose markers in DBS indicates that high concentrations of dextrose were present in blood and the likely source was contamination by TPN solutions most likely occurring during a sample collection process. |
Comparison of amino acids and acylcarnitines assay methods used in newborn screening assays by tandem mass spectrometry
De Jesus VR , Chace DH , Lim TH , Mei JV , Hannon WH . Clin Chim Acta 2010 411 684-9 BACKGROUND: The analysis of amino acids (AA) and acylcarnitines (AC) by tandem mass spectrometry (MS/MS) is performed in newborn screening laboratories worldwide. While butyl esterification assays are routine, it is possible to detect AAs and ACs as their native free acids (underivatized). The Centers for Disease Control and Prevention's Newborn Screening Quality Assurance Program provides dried-blood spot (DBS) quality control (QC) and proficiency testing (PT) programs for numerous MS/MS analytes. We describe empirical differences between derivatization and non-derivatization techniques for selected AAs and ACs. METHODS: DBS materials were prepared at levels near, above and below mean domestic laboratory cut-offs, and distributed to program participants for MS/MS analysis. Laboratories reported quantitative and qualitative results. QC DBS materials were assayed in-house following established protocols. RESULT: Minor differences (<15%) between quantitative values resulting from butyl esters and free acid techniques were observed for the majority of the analytes. Mass spectrometric response from underivatized dicarboxylic acid acylcarnitines was less intense than their butyl esters. CONCLUSIONS: The use of underivatized techniques may also result in the inability to differentiate isobaric acylcarnitines. Laboratories should establish their own protocols by focusing on the decisions that identify test results requiring additional follow-up testing versus those that do not. |
Preliminary proficiency testing results for succinylacetone in dried blood spots for newborn screening for tyrosinemia type I
Adam BW , Lim TH , Hall EM , Hannon WH . Clin Chem 2009 55 (12) 2207-13 BACKGROUND: Succinylacetone (SUAC) is the primary metabolite accumulated in tyrosinemia type I-an inborn error of metabolism that, if untreated, can cause death from liver failure during the first months of life. Newborn screening laboratories measure SUAC in dried blood spot (DBS) samples to detect asymptomatic tyrosinemia type I. We used panels of SUAC-enriched DBSs to compare and evaluate the performance of these screening tests. METHODS: We prepared sets of DBS materials enriched with predetermined SUAC concentrations and distributed samples of these materials, along with a screening practices questionnaire, to laboratories that perform SUAC tests. We compared their reported SUAC concentrations and questionnaire responses to identify screening practices that affect SUAC test outcomes. RESULTS: Data from 2 pilot surveys showed large differences among laboratories in SUAC recoveries, reproducible within-laboratory recoveries, and stable performance of the DBS materials. Results from 257 proficiency test analyses contained a total of 6 false-negative misclassifications. Reported recoveries of added SUAC ranged from 0 to >200%. Low-biased SUAC recoveries were associated with 1 method used by 5 laboratories. All laboratories that reported SUAC recoveries ≥100% used DBS matrix calibrators. CONCLUSIONS: The wide ranges of SUAC concentrations reported for pilot and proficiency testing specimens demonstrate a need to harmonize quantitative results among laboratories. Although DBS matrix calibrators are important for optimizing SUAC recoveries, the preparation of these calibrators is not standardized among laboratories. Certified DBS-based SUAC calibrators are needed for accuracy and harmonization. |